Objective: To establish reliability of cephalometric landmark identification in threedimensions using ProPlan CMF software.
Methods: Two orthodontist identified a series of 33 cephalometric landmarks on 20 CBCT scans of Class I, pre-orthodontic patients and repeated the landmark identification about two months later. Intraclass correlations (ICC) were calculated by landmark in the X, Y, and Z dimensions and F-test were used to assess difference in landmark location in the X, Y, and Z dimensions.
Results: The majority of landmarks had good to excellent ICC for both inter- and intraobserver reliability. F-test also showed the majority of landmarks had no significant difference between the observers.
Conclusion: Most landmarks showed good to very good reliability and reproducibility using ProPlan CMF, with some landmarks proving more reliable than others and further research is needed to establish the utility and practicality of three-dimensional cephalometrics as a common diagnostic tool in orthodontics.
Identifier
Manuscript ID: JDDM-1-104
Recommended Citation
Levine TP, Matthews GJ, Calero HF, Badner VM. Comparison of Inter and IntraOperator Differences for Cephalometric Landmark Identification on Three-Dimensional CBCT Images using Pro Plan CMF. J Dents Dent Med. 2018 Jan;1(1):104
Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright Statement
© The Authors, 2018.
Comments
Author Posting © The Authors, 2018. This article is posted here by permission of the Authors for personal use, not for redistribution. The article was published in Journal of Dentistry and Dental Medicine, Volume 1, Issue 1, January 2018, http://dx.doi.org/10.31021/jddm.20181104